1,344 LSlimline1300 Litre Slimline Bunded Diesel Tank
- Capacity
- 1,344 litres
- Size (mm)
- 2,300 x 950 x 1,850

A diesel dispensing tank stores your fuel and lets you pump it straight into vehicles and machinery. No trips to the forecourt, no jerry cans, and the pump and nozzle are locked away when you’re not using them. We supply and install the Harlequin range of bunded Fuel Points and Fuel Stations, from 1,300 to 9,250 litres.

Cost-effective diesel storage and dispensing
A bunded tank with a lockable dispensing cabinet for the pump, hose and nozzle. Add a mechanical flow meter, particulate filter or electronic gauge as needed. Includes the 5,000 litre AGRI model for farms.
View 6 Bunded Fuel Points
Higher-spec dispensing for busier sites
The same bunded protection with room for higher-spec equipment, such as a high-speed fuel pump and a fuel management system that records who draws fuel and how much.
View 8 Bunded Fuel StationsAt most sizes the Fuel Point and Fuel Station use the same bunded tank. The difference is the dispensing equipment inside the cabinet, so each size below shows the versions available.
1,344 LSlimline
1,498 L
2,530 LSlimline
2,571 L
3,553 L
5,307 L
5,314 LAgricultural
8,088 L
9,382 L*Brimful capacity.
The base size is the concrete pad the tank needs. We check your site can take it during the survey.
| Tank | Type | Capacity | L x W x H | Base size |
|---|---|---|---|---|
| 1300 Litre Slimline Bunded Fuel Point (1300SLFP) | Bunded Fuel Point | 1,344 litres | 2,300 x 950 x 1,850 mm | 2,900 x 1,550 mm |
| 1300 Litre Slimline Bunded Fuel Station (1300SLFS) | Bunded Fuel Station | 1,344 litres | 2,300 x 950 x 1,850 mm | 2,900 x 1,550 mm |
| 1400 Litre Bunded Fuel Point (1400FP) | Bunded Fuel Point | 1,498 litres | 1,610 x 1,570 x 1,880 mm | 2,210 x 2,170 mm |
| 1400 Litre Bunded Fuel Station (1400FS) | Bunded Fuel Station | 1,498 litres | 1,610 x 1,570 x 1,880 mm | 2,210 x 2,170 mm |
| 2500 Litre Slimline Bunded Fuel Point (2500SLFP) | Bunded Fuel Point | 2,530 litres | 2,550 x 1,385 x 1,985 mm | 3,150 x 1,985 mm |
| 2500 Litre Slimline Bunded Fuel Station (2500SLFS) | Bunded Fuel Station | 2,530 litres | 2,550 x 1,385 x 1,985 mm | 3,150 x 1,985 mm |
| 2500 Litre Bunded Fuel Point (2500FP) | Bunded Fuel Point | 2,571 litres | 2,060 x 2,020 x 1,880 mm | 2,660 x 2,620 mm |
| 2500 Litre Bunded Fuel Station (2500FS) | Bunded Fuel Station | 2,571 litres | 2,060 x 2,020 x 1,880 mm | 2,660 x 2,620 mm |
| 3500 Litre Bunded Fuel Point (3500FP) | Bunded Fuel Point | 3,553 litres | 2,200 x 2,200 x 2,060 mm | 2,800 x 2,800 mm |
| 3500 Litre Bunded Fuel Station (3500FS) | Bunded Fuel Station | 3,553 litres | 2,200 x 2,200 x 2,060 mm | 2,800 x 2,800 mm |
| 5000 Litre Bunded Fuel Station (5000FS) | Bunded Fuel Station | 5,307 litres | 2,720 x 2,220 x 2,360 mm | 3,320 x 2,820 mm |
| 5000 Litre Agricultural Bunded Fuel Point (5000FP AGRI) | Bunded Fuel Point | 5,314 litres | 2,360 x 2,360 x 2,210 mm | 2,810 x 2,960 mm |
| 7500 Litre Bunded Fuel Station (7500FS) | Bunded Fuel Station | 8,088 litres | 2,940 x 2,305 x 2,820 mm | 3,540 x 2,905 mm |
| 9250 Litre Bunded Fuel Station (9250FS) | Bunded Fuel Station | 9,382 litres (brimful) | 3,140 x 2,510 x 2,820 mm | 3,740 x 3,110 mm |
Refuel tractors and machinery in the yard instead of driving to a forecourt.
Keep plant running on site, with the pump locked away when the site is closed.
Fuel vehicles at the depot and keep track of what each one uses.
Supply generators, forklifts and site vehicles from one secure tank.
In England, businesses storing more than 200 litres of oil, including diesel, generally need secondary containment under the Oil Storage Regulations. Farms storing fuel for agricultural use have their own rules. A bunded dispensing tank meets the containment requirement in a single unit. We’ll advise on siting, the base and security when we survey your site.
FAQs
Can’t see your question? Our team can advise on sizes, pumps and siting for your site.
It’s a diesel storage tank with the dispensing equipment built in: a pump, hose and nozzle, kept in a lockable cabinet. You refuel vehicles and machinery straight from the tank on your own site.
The Harlequin range we supply runs from 1,300 litres up to 9,250 litres. Slimline models (1,300 and 2,500 litres) are only 950 mm and 1,385 mm wide, for sites where space is tight.
Usually, yes. In England, businesses storing more than 200 litres of oil, including diesel, need secondary containment that holds at least 110% of the tank’s contents. Farms follow separate rules for agricultural fuel oil. Every tank on this page is bunded.
Both store and dispense diesel from a bunded tank. Fuel points are the cost-effective option. Fuel stations can take higher-spec equipment, such as a high-speed pump and a fuel management system. We’ll recommend the right one for how much fuel you use.
These tanks are designed for diesel and gas oil. Tell us exactly what you’ll store, including HVO, and we’ll confirm the tank, pump and fittings are suitable.
Yes. We survey the site, advise on the concrete base and position, then deliver, install and commission the tank across Lincolnshire, Nottinghamshire, Yorkshire and Rutland.
Tell us what you refuel and roughly how much diesel you use each week. Call 01673 572222 or send us an enquiry for a free quote.